Product Code: 200067465

Address:

Guangdong,China

Main Products:

gas sensor,temperature and humidity sensor,UV Sensors,Ultrasonic Sensors,Fiber Optic Sensors,Liquid Level Sensors

Contact Info. Chat Online
FSM-10H-01 Pre-calibrated Combustible Gas Sensor Module
  • FOB Price
    US $ 10.00 - 100.00 / Piece(s)
  • Min. Order
    1 Piece(s)
  • Payment Terms
    T/T, Paypal
  • Port
    HK
  • Delivery Time
    7 days after payment
  • Place of Origin:
    China
  • Brand Name:
    Figaro
  • Model Number:
    FSM-10H-01
  • Usage:
    Gas Sensor
  • Theory:
    Other
  • Output:
    Analog Sensor
  • Detection ra...:
    0 ~ 4,000ppm H2
  • Error :
    ± 300ppm
  • Response tim...:
    ≤30S
  • Operation te...:
    -10°C ~+70°C
  • Operation hu...:
    20~95%RH(No condensin...
  • Power consum...:
    ≤1.5W​
Product Description

FSM-10H-01 Pre-calibrated Module for LPG Gas
FSM-10H-01 is Pre-calibrated Module for LPG gas alarm which applies TGS2610-D00 sensor together, it features durability and stability. The module  outputs  PWM  signal which  is proportional to LPG gas concentration (The module has a memory which is stored with factory calibration data), also is capable of detecting sensor wire breakage and short. The module can operate at wide temperature from -10~70°C.

Furthermore, the unit is less sensitivity to VOCs gas, it immunes poison by silicon compounds, it suits to work at rugged environment.

FSM-10H-01 Combustible Gas Sensor Module Features
• PWM, USART digital output proportional to gas concentration
• Maintain Free
• Compact size, low cost
• Meets RoHS requirement

FSM-10H-01 Combustible Gas Sensor Module Applications
• Detect flammable gas leakage
• Flammable gas leakage Detector
• Industrial detector

FSM-10H-01 Combustible Gas Sensor Module Specification

Product name
Combustible gas sensor module
Model No.
FSM-10H-01
Gas sensor
TGS2610-D00(Semiconductor)
Detection range
0 ~ 4,000ppm H2
(also can detect methane, iso-butane, and propane)
Error
± 300ppm
Output voltage
(Vconc)
PWM(2KHz)
Trouble
Trouble:H, Normal:L
Response time (T90)
≤30S
Operating conditions
-10°C ~+70°C, 20~95%RH(No condensing)
Storage conditions
-10°C ~+80°C, 20~95%RH
Input voltage (VIN)
5.0±0.2V DC
Power consumption
≤1.5W
Weight
15g or less
Dimensions
26*27mm
Standard test conditions
Ambient conditions
20±2°C, 65±5%RH
Circuit conditions
5.0±0.2V
Conditioning period
prior to test
≥10 minutes